Address Name Default seng Category Data type Factor A M
0x2637:011
(P431.11)
Analog input 2: Min torque value 0.0 % general I16 10 P -
0x2637:012
(P431.12)
Analog input 2: Max torque value 100.0 % general I16 10 P -
0x2639:001
(P440.01)
Analog output 1: Output range 0 ... 10 VDC [1] general U8 1 P -
0x2639:002
(P440.02)
Analog output 1: Funcon Output frequency [1] general U8 1 P -
0x2639:003
(P440.03)
Analog output 1: Min. signal 0 general I32 1 P -
0x2639:004
(P440.04)
Analog output 1: Max. signal 1000 general I32 1 P -
0x2820:001
(P712.01)
Holding brake control: Brake mode O [2] general U8 1 P r
0x2820:002
(P712.02)
Holding brake control: Brake closing me 100 ms general U16 1 P -
0x2820:003
(P712.03)
Holding brake control: Brake opening me 100 ms general U16 1 P -
0x2820:007
(P712.07)
Holding brake control: Brake closing threshold 0.2 Hz general U16 10 P -
0x2820:008
(P712.08)
Holding brake control: Brake holding load 0.0 % general I16 10 PC -
0x2820:012
(P712.12)
Holding brake control: Closing threshold delay 0 ms general U16 1 P -
0x2820:013
(P712.13)
Holding brake control: Holding load rampme 0 ms general U16 1 PC -
0x2820:015
(P712.15)
Holding brake control: Brake status - (Read only) general U8 1 - -
0x2822:004
(P327.04)
Idenfy motor data (energized) 0 general U8 1 - -
0x2822:005
(P327.05)
Calibrate motor data (non-energized) 0 general U8 1 - -
0x2822:019 Calculate Imax controller parameter 0 general U8 1 - -
0x2824
(P200.00)
Control selecon Flexible I/O
conguraon
[0]
general U8 1 P -
0x2825 Drive mode selecon CiA402 operang modes
[0]
general U8 1 C -
0x2826 Time-out for error response 6.0 s general U16 10 P -
0x2827
(P198.00)
Currently loaded parameter sengs - (Read only) general U8 1 - -
0x2829
(P732.00)
Automac storage in the memory module Inhibit [0] general U8 1 P -
0x282A:001
(P126.01)
Status words: Cause of disable - (Read only) general U32 1 O -
0x282A:002
(P126.02)
Status words: Cause of quick stop - (Read only) general U16 1 O -
0x282A:003
(P126.03)
Status words: Cause of stop - (Read only) general U16 1 O -
0x282A:004 Status words: Extended status word - (Read only) general U16 1 O t
0x282A:005
(P126.05)
Status words: Device status - (Read only) general U8 1 O t
0x282B:001
(P125.01)
Inverter diagnoscs: Acve control source - (Read only) general U8 1 O t
0x282B:002
(P125.02)
Inverter diagnoscs: Acve setpoint source - (Read only) general U8 1 O t
0x282B:003
(P125.03)
Inverter diagnoscs: Keypad LCD status - (Read only) general U8 1 O -
0x282B:004
(P125.04)
Inverter diagnoscs: Acve drive mode - (Read only) general U8 1 O t
* Default seng dependent on the model.
Appendix
P
arameter aribute list
319