Diagnostic information 2-11
5060-4xx
117 Printhead Error A yellow printhead servo error has been detected.
Verify all packing material have been removed from the printer and the
printhead.
If error persists, see “Printhead diagnostics” on page 3-1.
120 Fuser Error Wrong fuser lamp - hot roll - replace the fuser assembly. See “Fuser
assembly” on page 4-35.
121 Fuser Error Wrong fuser lamp - BUR - replace the fuser assembly. See “Fuser
assembly” on page 4-35.
122 Fuser Error Fuser below temperature when printing - hot roll - go to “122 error code”
on page 2-46.
123 Fuser Error Fuser below temperature when printing - BUR - go to “123 error code”
on page 2-46.
124 Fuser Error Fuser over temperature - hot roll - go to “124 error code” on page 2-47.
125 Fuser Error Fuser over temperature - BUR - go to “125 error code” on page 2-47.
126 Fuser Error Fuser open thermistor hot roll - go to “126 error code” on page 2-48.
127 Fuser Error Fuser open thermistor BUR - go to “127 error code” on page 2-48.
128 Fuser Error Fuser under temperature in standby - hot roll - go to “128 error code” on
page 2-49.
129 Fuser Error Fuser under temperature in standby - BUR - go to “129 error code” on
page 2-49.
130 Fuser Error Fuser failed to reach standby temperature - hot roll - go to “130 error
code” on page 2-50.
131 Fuser Error Fuser failed to reach standby temperature -BUR - go to “131 error
code” on page 2-51.
132 Fuser Error Fuser cold hot roll - go to “132 error code” on page 2-52.
133 Fuser Error Fuser cold roll - BUR - go to “133 error code” on page 2-53.
134 Fuser Error Fuser lamp on too long hot roll - go to “134 error code” on page 2-54.
135 Fuser Error Fuser lamp on too long BUR - go to “135 error code” on page 2-54.
136 Fuser Error Fuser cam position not found - go to “136 error code” on page 2-54.
140 Motor DC motor accel stall - registration (staging)- replace the “Registration
motor” on page 4-69.
If this does not fix the problem, replace the “System board” on
page 4-72.
Error code Action