Chapter 8 Troubleshooting
223
Points to check Corrective action
Does the media have ripples/surface
irregularities or lift up?
If you are using roll media, use a smooth section of the media for
initial feeding. You can also improve this problem by attaching the
NITOFLON
®
tape provided on the platen.
Attach the tape, taking care not to block the vacuum
hole.
For more information, refer to the description on transporting media
on the platen. https://mimaki.com/download/inkjet.html
Image Defects Occur.
Symptom Corrective action
White streaks, blurriness, and dark
streaks occur.
(Carriage scan direction)
1. Remove any paper scraps or other debris adhering to areas over which
the head passes (e.g., media holders). "Media Holder
Cleaning"(P. 189) "Platen Cleaning"(P. 191)
2. Perform the procedure described in "Head Cleaning"(P. 81).
3. Perform the procedure described in "Feed Correction"(P. 82).
4. Perform the procedure described in "Cap Rubber Cleaning"(P. 182).
5. Perform the procedure described in "Carriage Underside
Cleaning"(P. 183).
Text is double- or triple-printed in the
media feed direction.
1. Perform the procedure described in "Feed Correction"(P. 82).
Offsetting occurs during bidirectional
printing.
1. Perform the procedure described in "Correcting the Drop
Position"(P. 84).
Ink droplets drip during printing.
1. Perform the procedure described in "Cap Rubber Cleaning"(P. 182).
2. Perform the procedure described in "Carriage Underside
Cleaning"(P. 183).
3. Perform the procedure described in "Head Cleaning"(P. 81).
4. Set auto maintenance. "Maintenance Menu"(P. 163)
Clear clogged nozzles.
1. Perform the procedure described in "Head Cleaning"(P. 81).
2. Perform the procedure described in "Print Head Nozzle
Washing"(P. 223).
3. Perform the procedure described in "Registering Nozzle
Recovery"(P. 165).
Print Head Nozzle Washing
If ejection failures (e.g., nozzle clogging or deflection) remain unresolved even after head cleaning (
"Head Cleaning"(P. 81)), apply nozzle wash to the print head.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.