Chapter 8 Troubleshooting
224
2
Select [Station Maint.] > [Nozzle Wash], then press the [ENTER] key.
• The carriage moves over the platen.
3
Open the maintenance cover on the right side.
4
Clean the cap rubber.
• "Cap Rubber Cleaning"(P. 182)
5
Once cleaning is complete, close the cover, then press the [ENTER] key.
• The cap is filled with maintenance liquid.
• Close the cover. The cap cannot be filled with maintenance liquid while the cover is open.
This is also true if the maintenance liquid cartridge is empty.
6
Open the maintenance cover on the right side.
• Check to confirm that the cap is filled with maintenance liquid.
• If not, use a syringe to draw up some maintenance liquid and fill until it almost overflows
from the cap.
7
Close the maintenance covers.
8
Set the exposure time, then press the [ENTER] key.
• Cleaning is performed automatically once print nozzle washing has ended.
• If ejection failures (e.g., nozzle clogging or deflection) remain unresolved even after
washing the nozzles several times, contact your local dealer or our service office.
The heater temperature does not rise to the specified value.
This may indicate a problem with the setting.
Points to check Corrective action
Is the 100V/200V selector
switch set correctly?
Set the selector switch according to the power supply voltage.
Is the heater temperature set? Set the heater temperature. "Setting the Heater Temperature"(P. 78)
"Media Setting Menu"(P. 160)