EasyManua.ls Logo

Mitel Inter-Tel 5000 - Trunking Capacity by Type of Module; Capacities of All-Trunk Systems

Mitel Inter-Tel 5000
468 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4: Specifications
Capacities of All-Trunk systems
Inter-Tel
®
5000 Installation Manual – Issue 2.4, May 2008 Page 4-39
Capacities of All-Trunk systems
Table 4-18 summarizes system trunk capacity in terms of the trunk module type and the
possible number of trunks provided in all-trunk systems. A typical installation may include a
combination of hard-wire trunks and IP gateway trunks. See also Table 4-10 on page 4-17 for
additional capacities, including IP.
Table 4-18. Trunking Capacity by Type of Module
Module
Type
Trunk/Span
Type
Modules
Ports or
Channels
per Module
Trunk
Capacity
Built-In
LS Ports
Total
Trunks
T1M E1/PRI 3 30 90 2 92
T1M-2 E1/PRI 3 30 180 2 182
T1M T1 3 24 72 2 74
T1M-2 T1 3 24 144 2 146
T1M T1/PRI 3 23 69 2 71
T1M-2 T1/PRI 3 23 138 2 140
LSM-2
a
a. No longer in production.
Loop Start 3 2 6 2 8
LSM-4 Loop Start 3 4 12 2 14
NA–CS-5200 IP Gateway
Trunks
b
b. Requires licensing and installation of enabling hardware.
0N/A32
3
234
NA–CS-5400
or CS-5600
IP Gateway
Trunks
2
0N/A32
c
c. Lab-test to 32 trunks. Actual capacity depends on the availability of IP resources, the vocoder used,
and the system configuration.
234