Program 12 : Night Mode Setup
12-02 : Automatic Night Service Patterns
Level:
SA
Description
Use Program 12-02 : Automatic Night Service Patterns to define the daily pattern of the Automatic
Mode Switching. Each Mode Group has 10 patterns. These patterns are used in Programs 12-03 and
12-04. The daily pattern consists of 20 timer Settings.
Input Data
Night Mode Service Group Number 01 ~ 04
Time Pattern Number 01 ~ 10
Set Time Number 01 ~ 20
Item
No.
Item Input Data Default
01 Start Time 0000 ~ 2359 Refer below
02 End Time 0000 ~ 2359 Refer below
03 Operation Mode 1 ~ 8 = Night Modes 1 ~ 8 Refer below
Example :
Time Pattern 1
0:00 9:00 12:00 13:00 17:00 18:00 22:00 0:00
Mode 3
(midnight)
Mode 3
(midnight)
Mode 2
(night)
Mode 1
(day)
Mode 1
(day)
Mode 4
(rest)
Mode 4
(rest)
To make the above schedule, it is necessary to set the data as follows:
Time setting 01 :
00 : 00 to 09 : 00 Mode 3 (midnight)
Time setting 02 : 09 : 00 to 12 : 00 Mode 1 (day)
Time setting 03 : 12 : 00 to 13 : 00 Mode 4 (rest)
Time setting 04 : 13 : 00 to 17 : 00 Mode 1 (day)
Time setting 05 : 17 : 00 to 18 : 00 Mode 4 (rest)
Time setting 06 : 18 : 00 to 22 : 00 Mode 2 (night)
Time setting 07 : 22 : 00 to 00 : 00 Mode 3 (midnight)
Time Pattern 2
00 : 00
00 : 00
Mode 2
(night)
ISSUE 3.01 SL1000/SL1100