Program 84 : Hardware Setup for VoIPDB
84-01 : H.323 Trunk Basic Information Setup
Level:
IN
Description
Use Program 84-01 : H.323 Trunk Basic Information Setup to set the basic information of the H.323
Trunk.
Input Data
Item
No.
Item Input Data Description Default
02 Number of G.711 au-
dio frames
1 ~ 4 3
03 G.711 VAD mode 0 = Disable
1 = Enable
0
04 G.711 Type 0 = A-law
1 = μ-law
0
05 Number of G.729 au-
dio frames
1 ~ 6 3
06 G.729 VAD mode 0 = Disable
1 = Enable
0
07 G.729 Jitter Buf-
fer( min)
0 ~ 300 ms 30
08 G.729 Jitter Buffer
(average)
0 ~ 300 ms 60
09 G.729 Jitter Buffer
(max)
0 ~ 300 ms 120
11 Number of G.723 au-
dio frames
1 ~ 2 1
15 Jitter Buffer Mode 1 = Fixed
3 = Self adjusting
3
16 G.711 Jitter Buf-
fer( min)
0 ~ 255 ms 30
17 G.711 Jitter Buffer
(average)
0 ~ 255 ms 60
18 G.711 Jitter Buffer
(max)
0 ~ 255 ms 120
19 G.723 Jitter Buf-
fer( min)
0 ~ 300 ms 30
20 G.723 Jitter Buffer
(average)
0 ~ 300 ms 60
21 G.723 Jitter Buffer
(max)
0 ~ 300 ms 120
ISSUE 3.01 SL1000/SL1100