Program 20 : System Option Setup
20-46 : Security Sensor Setup
Level:
IN
Description
Use Program 20-46 : Security Sensor Setup to defines the security sensor.
Input Data
Security Sensor Number 1 ~ 8 (SL1000)
1 ~ 6 (SL1100)
Item
No.
Item Input Data Description Default
01 Sensor Mode 0 = Off
1 = On
Define door port (408M 6, 7 (SL1000)
084M 3, 4 (SL1100)) to use as Sensor.
0
02 Internal Paging Group
for Warning Message
0 ~ 32 Define Internal paging group number for
Warning message
0
03 Ring Timer 0 ~ 8 Define External paging group number for
Warning message.
0
04 VRS Message for
Warning
0 ~ 100 Define VRS number used for Warning
message.
0
05 Auto Dial Number
Area Setting
0 ~ 999 Define Speed dial number when sensor
detects warning.
0
06 VRS Message for An-
swer
0 ~ 100 Define VRS message number when emer-
gency call destination answered.
0
07 Auto Dial Wait Timer 0 ~ 64800 Define wait time before making emergency
auto dial.
30
08 Time of Repeat Auto
Dial
0 ~ 255 Define repeat number for making emer-
gency call.
3
09 Auto Dial Calling
Time
0 ~ 64800 Define calling continue time when making
emergency call.
30
10 Monitored Terminal Extension Number (Up
to 4 digits) (SL1000)
Extension Number (Up
to 8 digits) (SL1100)
Define extension number for monitor from
outside. IP terminal cannot set as moni-
tored extension.
No Setting
11 Interval of Auto Dial 0 ~ 3600 0
Conditions
None