Program 21 : Outgoing Call Setup
21-05 : Toll Restriction Class
Level:
IN
Description
Use Program 21-05 : Toll Restriction Class to set the system Toll Restriction classes (1 ~ 15).
Input Data
Toll Restriction Class Number 1 ~ 15
Item
No.
Item Input Data Description Default Related
Program
01 International Call
Restriction Table
0 = Unassign (No inter-
national restrict table
applied.)
1 = Assign (Table in
PRG 21-06-01 is ap-
plied.)
This option assigns/unassigns the
International Call Restrict Table for
the Toll Restriction Class you are
programming. Enter International
Call Restrict Table data in Program
21-06-01.
0 21-06-01
02 International Call
Permit Code Ta-
ble
0 = Unassign (No inter-
national permit table
applied.)
1 = Assign (Table in
PRG 21-06-02 is ap-
plied.)
This option assigns/unassigns the
International Call Permit Table for
the Toll Restriction Class you are
programming. Enter International
Call Permit Table data in Program
21-06-02.
0 21-06-02
04 Maximum Num-
ber of Digits Ta-
ble Assignment
0 = No Table Applied
1 ~ 4 = Tables 1 ~ 4
( Defined in PRG
21-06-03)
Select the table (defined in
21-06-03) to be used to determine
the maximum number of digits al-
lowed for outgoing calls.
0 21-06-03
05 Common Permit
Code Table
0 = Unassign (No com-
mon permit table ap-
plied.)
1 = Assign (Table in
PRG 21-06-04 is ap-
plied.)
It chooses whether the table set up
by 21-06-04 is referred to, or not re-
ferred to.
0 21-06-04
06 Common Re-
striction Table
0 = Unassign (No com-
mon restrict table ap-
plied.)
1 = Assign (Table in
PRG 21-06-05 is ap-
plied.)
It chooses whether the table set up
by 21-06-05 is referred to, or not re-
ferred to.
0 21-06-05
07 Permit Code Ta-
ble
0 = No Permit Table
Assigned
1 ~ 4 = Permit Tables 1
~ 4 (assigned in PRG
21-06-06)
Set the tables 1 ~ 4 when referring
to the table set up by 21-06-06.
0 21-06-06
08 Restriction Table 0 = No Permit Table
Assigned
1 ~ 4 = Restrict Tables
1 ~ 4 (assigned in PRG
21-06-07)
Set the tables 1 ~ 4 when referring
to the table set up by 21-06-07.
0 21-06-07