Program 34 : Tie Line Setup
34-11 : E1 Trunk Basic Setup
Level:
IN
Description
Use Program 34-11 : E1 Trunk Basic Setup to define the basic setting of each E1 Trunk.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Item
No.
Item Input Data Description Default
01 E1 Trunk Type 0 = Standard Trunk
1 = Argentine Pulsed
Clear Back Trunk
2 = Argentine Pulsed
Answer Trunk
3 = Brazil With seizure
acknowledge Trunk
4 = Brazil Without seiz-
ure acknowledge Trunk
5 = Brazil E&M Signal A
(Idle = 0) Trunk
6 = Brazil E&M Signal A
(Idle = 1) Trunk
7 = Brazil E&M Signal B
(Idle = 0) Trunk
8 = Brazil Code for col-
lect call blocking Trunk
Use this option to specify the E1 Signal
type (0 ~ 8). Set this option for compatibili-
ty with the connected Telco.
0
02 MFC Dialing Type 0 = MFC Dialing not
used
1 = NEC Standard
2 = Argentina
3 = Brazil
4 = Chile
5 = Colombia
6 = Mexico
7 = Venezuela
Use this option to specify the MFC Dialing
Type. The following table shows the avail-
able MFC Dialing Type choices, By de-
fault, this option is 0 (MFC Dialing not
used).
0
03 MFC Group B 0 = Disable
1 = Enable
Use this option to enable (1) or disable (0)
the MFC Dialing Group B supervisory sig-
naling. Since not all central offices provide
Group B signaling, set this option for com-
patibility with the connected Telco. By de-
fault, this option is Disable (0).
0
04 Expected Number of
MFC Digits
0 ~ 20 Use this option to specify the number of
digits in the ANI number. This is required
for ANI since delimiters do not mark the
beginning and end of the data string. The
system must know how many digits of in-
coming ANI Caller ID data to interpret.
7
SL1000/SL1100 ISSUE 3.01
2-368 Program 34 : Tie Line Setup
Program