Program 10 : System Configuration Setup
10-61 : Relay Port Setup
Level:
IN
Description
Use Program 10-61 : Relay Port Setup to defines the relay port type on the 408M (SL1000) 084M
(SL1100).
Input Data
Relay Port No. 1 ~ 8 (SL1000)
1 ~ 6 (SL1100)
Item
No.
Item Input Data Default
01 Relay Type 0 = No Setting
1 = External MOH
2 = BGM resource
3 = External Speaker
4 = Door Phone
0
02 Destination Selection 10-61-01 = 1 or 2 : Not Use
10-61-01 = 3 : 1 ~ 3 External Speaker Message
No.
10-61-01 = 4 : 1 ~ 8 Door Phone No. (SL1000)
10-61-01 = 4 : 1 ~ 6 Door Phone No. (SL1100)
0 (Not Used)
Conditions
None
Feature Cross Reference
None
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-57