Program 25 : VRS/DISA Setup
25-07 : System Timers for VRS/DISA
Level:
IN
Description
Use Program 25-07 : System Timers for VRS/DISA to set the value for the system timers which
affect DID and DISA. Refer to the following chart for a description of each option, its range and default
setting.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 VRS/DISA Dial
Tone Time
0 ~ 64800 seconds After answering a DISA trunk, the
system waits this time for the caller
to dial the first digit of the DISA
password. If the caller fails to dial
during this time, the system drops
the call.
10 25-04
02 VRS/DISA No An-
swer Time
0 ~ 64800 seconds A VRS/DISA caller can ring an ex-
tension for this time before the sys-
tem sets the call as a Ring No An-
swer. After this time expires, the call
follows the programmed Ring No
Answer routing (set in Programs
25-03 and 25-04).
10 25-04
20-31-17
03 Disconnect after
VRS/DISA re-
transfer to IRG
0 ~ 64800 seconds From DISA trunk, when the call may
go to Incoming Ring Group of Pro-
grams 25-03 and 25-04. This setting
determines how long the call is ring-
ing in the IRG.
60 20-31-18
04 Calling Time to
Automatic An-
swering Tele-
phone Set
0 ~ 64800 seconds Set the answering waiting time of
the automatic answering extension
when an incoming DID trunk call is
received.
10
05 Duration Time
for Guidance
Message by Au-
tomatic Answer-
ing Telephone
Set
0 ~ 64800 seconds Set the announcement time of the
automatic answering extension after
which an incoming DID trunk caller
is disconnected.
10
07 Long Conversa-
tion Warning
Tone Time
0 ~ 64800 seconds Determine the time a DISA caller or
any trunk-to-trunk (such as Tandem
Trunking) conversation can talk be-
fore the Long Conversation tone is
heard.
30 14-01-25
20-28-01
20-28-02
20-28-03
20-31-19
08 Long Conversa-
tion Disconnect
Time
0 ~ 64800 seconds This time determines how long the
system waits before disconnecting a
DISA caller or any trunk-to-trunk
(such as Tandem Trunking) conver-
sation call after the Long Conversa-
tion tone is heard.
15 14-01-25
20-28-01
20-28-02
20-28-03