Program 90 : Maintenance Program
90-10 : System Alarm Setup
Level:
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate
an alarm as Major or Minor. This program also assigns whether or not the alarm information is
reported to the pre-defined destination.
Input Data
Alarm Number 001 ~ 100
Item
No.
Item Input Data Default
01 Alarm Type 0 = Not Set
1 = Major Alarm
2 = Minor Alarm
-
02 Report 0 = Not Report (No autodial)
1 = Report (autodial)
-
Table 2-20 Description of Alarm
Alarm
No.
Type
Re-
port
Name
Content of
Alarm
Cause Action Recovery
Alarm
Status
1 2 0 PKG Initi-
alize Er-
ror.
1. The PKG
failed to ini-
tialize.
2. The PKG
did not start
normally.
1. PKG not inser-
ted firmly.
2. PKG was re-
moved, but
not reinserted
firmly.
3. Old PKG data
still reported
due to no initi-
alization.
1. Insert PKG
firmly.
2. Insert PKG
firmly.
3. Delete slot in-
formation in
Program
90-05 and in-
sert the PKG
again.
During initiali-
zation, the
PKG is rec-
ognized.
ERR
REC
2 2 0 PKG
Mounting
Error
The unit did not
step on a regu-
lar procedure
and it was
pulled out.
Or, it is not nor-
mally inserted.
1. The package
is not com-
pletely inser-
ted.
2. The package
is out of order.
1. Please insert
the package
firmly.
2. Please try
again after ini-
tializing the
system data
once when
LED doesn't
blink normally.
3. Exchange
packages.
When unit is
reconfirmed,
the error is
recovered.
ERR
REC
SL1000/SL1100 ISSUE 3.01
2-558 Program 90 : Maintenance Program