Program 25 : VRS/DISA Setup
25-05 : VRS/DISA Error Message Assignment
Level:
IN
Description
Use Program 25-05 : VRS/DISA Error Message Assignment to assign the VRS message number to
be used as the Automated Attendant error message. For each VRS/DISA trunk that the VRS answers,
enter the VRS message (1 ~ 100) the outside caller hears if they dial incorrectly. If you enter 0 (i.e., no
error message), the call reroutes according to Programs 25-03 and 25-04.
For each trunk, make a separate entry for each Night Service mode.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Day/Night Mode 1 ~ 8
Item
No.
Item Input Data Default
01 VRS Message Number 0 ~ 100
(0 = No Setting)
0
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
ISSUE 3.01 SL1000/SL1100