Program 22 : Incoming Call Setup
22-07 : DIL Assignment
Level:
IN
Description
Use Program 22-07 : DIL Assignment to assign the destination extension or Department Calling
Group for each DIL Incoming trunk. A DIL rings an extension directly, without any other Access Map or
Ring Group programming. If an extension has a line key, the DIL rings the line key. Use Program
22-02 to designate a trunk as a DIL. You can make eight DIL assignments, one for each Night Service
mode.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Day/Night Mode 1 ~ 8
Item
No.
Item Input Data Default
01 Number of Transferring Destina-
tion
Assign extension or department group number
for DIL trunk
Extension Number (maximum four digits
(SL1000) maximum eight digits (SL1100))
No Setting
Conditions
Program 22-02 must be set to four for the trunk.
Feature Cross Reference
Direct Inward Line (DIL)
SL1000/SL1100 ISSUE 3.01