Program 90 : Maintenance Program
90-04 : Load Data
Level:
SA
Description
Note: This program is available only via telephone programming and not through PC Programming.
Use Program 90-04 : Load Data to load the system data from the inserted CF Card into the PZ-VM21
Daughter Board installed to the system.
Input Data
Item
No.
Item Input Data Default
01 Load Data Dial 1 + press Hold (Press Hold only to cancel.) -
Conditions
• After uploading the data the display will change to a next Program. Then make sure you EXIT the
Program order for upload to complete. Now some of the setting needs to have system reset order
for setting to be effective (example: IP Address, Line Key Assignment) so we Recommend to reset
the system.
• When installing a compact flash card onto the PZ-VM21 the system MUST be powered off. Never
install or uninstall the compact flash card while the system is under power.
Feature Cross Reference
None
SL1000/SL1100 ISSUE 3.01
2-552 Program 90 : Maintenance Program
Program
90