Program 81 : Basic Hardware Setup for Trunk
81-13 : E1 Trunk Timer Setup
Level:
IN
Description
Use Program 81-13 : E1 Trunk Timer Setup to define the basic timer setting of E1 Trunk.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Item
No.
Item Input Data Default
01 Loop Current Detection Time
(Loop)
1 ~ 255 (16 ms ~ 4080 ms) 3 (48 ms)
02 Clear Signal (Open Loop) Detec-
tion Time
1 ~ 255 (16 ms ~ 4080 ms) 50 (800 ms)
03 Transmit Clear Signal Time for
Forced Release
1 ~ 255 (16 ms ~ 4080 ms) 50 (800 ms)
04 Receive DP Inter-digit min. Time 1 ~ 255 (4 ms ~ 1020 ms) 125 (500 sec)
16 Pause Time 1 ~ 255 (64 ms ~ 16320 ms) 47 (3008 ms)
17 Pulse Dial Break Time 1 ~ 255 (4 ms ~ 1020 ms) 15 (60 ms)
18 Pulse Dial Make Time 1 ~ 255 (4ms ~ 1020ms) 10 (40 ms)
19 Pulse Dial Inter-digit Time 1 ~ 255 (16 ms ~ 4080 ms) 50 (800 ms)
20 Receive DP Make min Time 1 ~ 255 (4 ms ~ 1020 ms) 3 (12 ms)
21 Receive DP Make max Time 1 ~ 255 (4 ms ~ 1020 ms) 19 (76 ms)
22 Receive DP Break min Time 1 ~ 255 (4 ms ~ 1020 ms) 5 (20 ms)
23 Receive DP Break max Time 1 ~ 255 (4 ms ~ 1020 ms) 26 (104 ms)
24 Transmit Answer duration Time 1 ~ 255 (8 ms ~ 2040 ms) 38 (304 ms)
25 Transmit Double Answer duration
Time
1 ~ 255 (64 ms ~ 16320 ms) 32 (2048 ms)
26 Receive Answer min Time 1 ~ 255 (8 ms ~ 2040 ms) 25 (200 ms)
27 Receive Answer max Time 1 ~ 255 (8 ms ~ 2040 ms) 50 (400 ms)
28 Receive Double Answer min Time 1 ~ 255 (64 ms ~ 16320 ms) 24 (1536 ms)
29 Receive Double Answer max Time 1 ~ 255 (64 ms ~ 16320 ms) 47 (3008 ms)
30 Transmit Seizure Acknowledge du-
ration Time
1 ~ 255 (4 ms ~ 1020 ms) 25 (100 ms)
31 Receive Seizure Acknowledge min
Time
1 ~ 255 (4 ms ~ 1020 ms) 25 (100 ms)
32 Receive Seizure Acknowledge max
Time
1 ~ 255 (4 ms ~ 1020 ms) 75 (300 ms)
33 Transmit Digit Acknowledge dura-
tion Time
1 ~ 255 (4 ms ~ 1020 ms) 25 (100 ms)
SL1000/SL1100 ISSUE 3.01
2-488 Program 81 : Basic Hardware Setup for Trunk