Program 90 : Maintenance Program
90-20 : Traffic Report Data Setup
Level:
IN
Description
Use Program 90-20 : Traffic Report Data Setup to define the details of the traffic report.
Input Data
Item
No.
Item Input Data Description Default
01 Call Traffic Output 0 = Not Measured
1 = Measure
0
03 All Line Busy Output 0 = Not Detected
1 ~ 256
(Report when the data
reaches the defined val-
ue)
0
04 DTMF Receiver Busy
Output
0 = Not Detected
1 ~ 256
(Report when the data
reaches the defined val-
ue)
0
05 Dial Tone Detector
Busy Output
0 = Not Detected
1 ~ 256
(Report when the data
reaches the defined val-
ue)
0
06 Caller ID Receiver
Busy Output
0 = Not Detected
1 ~ 256
(Report when the data
reaches the defined val-
ue)
0
07 Voice Mail Channel
All Busy Output
0 = Not Detected
1 ~ 256
(Report when the data
reaches the defined val-
ue)
0
09 Attendant Channel All
Busy Output
0 = Not Detected
1 ~ 256
(Report when the data
reaches the defined val-
ue)
0
11 Security Sensor Dial
Record
0 = Not Recorded
1 = Recorded
Record Security sensor dialing and Re-
mote Inspection dialing to security report
1
Conditions