Program 22 : Incoming Call Setup
22-17 : Dial-In Conversion Table Area Setup for Time
Pattern
Level:
SA
Description
Use Program 22-17: Dial-In Conversion Table Area Setup for Time Pattern to define Time Zone
and Dial-In Conversion Table (Program 22-11) for Time Pattern.
Input Data
Conversion Table Number 001 ~ 500 (V2.0 Changed)
Time Pattern Number 1 ~ 8
Item
No.
Item Input Data Description Default
01 Received Dial Up to eight digits No Setting
02 Start of Time 0000 ~ 2359 (Time) Define the Starting Time for each DID
Translation table in PRG 22-17-01.
0000
03 End of Time 0000 ~ 2359 (Time) Define the Ending Time for each DID
Translation table in PRG 22-17-01.
0000
04 Dial-In Conversion
Table Number
1 ~ 800 (These are the
table entries in PRG
22-11.)
0
05 Day of week (V2.0
Added)
1: Sun
2: Mon
3: Tue
4: Wed
5: Thu
6: Fri
8: Sun
9: Holiday
0 = Off
1 = On
Assign Day of Week for each DID conver-
sion table.
1