Program 20 : System Option Setup
20-19 : System Options for Caller ID
Level:
IN
Description
Use Program 20-19 : System Options for Caller ID to define the system options for the Caller ID
feature.
Input Data
Item
No.
Item Input Data Description Default
01 Caller ID Displaying
Format
0 = First 10 digits (Up-
per)
1 = Last 10 digits (Low-
er)
(if displaying digits are more than 12 digits) 0
02 Caller ID Wait Timer 0 ~ 30 seconds When an incoming CO call is received, the
SL1000/SL1100 starts the timer. It will wait
the programmed time for Caller ID infor-
mation from Telco before connecting the
CO call.
5
03 Caller ID Edit Mode 0 = Off
1 = On
If Caller ID Edit Mode is disabled (0), no
access code will be added to the Caller ID.
If this option is enabled (1), the access
code entered in PRG 10-02-02 & 10-02-03
will be added to the beginning of the Caller
ID.
0
04 Wait Facility IE Timer 0 ~ 64800 seconds This timer is used with ISDN trunks to de-
termine how long the system waits for the
Caller ID name from the Telco.
10
05 Caller ID Sender
Queuing Time (Send-
er Wait)
0 ~ 64800 seconds 0
07 Long Distance Code Up to two digits No Setting
08 Area Code Up to six digits No Setting
Conditions
None
Feature Cross Reference
Caller ID
ISSUE 3.01
SL1000/SL1100
Programming Manual 2-207