EasyManua.ls Logo

NEC SL 1000 - E&M Tie Line Timer

NEC SL 1000
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 34 : Tie Line Setup
34-07 : E&M Tie Line Timer
Level:
IN
Description
Use Program 34-07 : E&M Tie Line Timer to define the system service tone timers.
Input Data
Item
No.
Item Input Data Default
01 First Digit Pause (E&M Immediate
Start)
0 ~ 64800 seconds 3
02 First Digit Pause (E&M Wink Start) 0 ~ 64800 seconds 0
03 First Digit Pause (LD Trunk) 0 ~ 64800 seconds 3
04 LD Trunk Guard Time 0 ~ 64800 seconds 0
05 Trunk Answer Detect Timer for
E&M
0 ~ 64800 seconds 30
Conditions
If Program 34-07-05 is left at default (30) the transferred call recalls to the station that performed the
transfer when not answered.
Feature Cross Reference
None
ISSUE 3.01 SL1000/SL1100