Program 90 : Maintenance Program
90-58 : Restore Recovery Data
Level:
SA
Description
Note: This program is available only via telephone programming and not through PC Programming.
Use Program 90-58 : Restore Recovery Data to select the recovery data stored in the Compact
Flash memory of the CPU. After this command is executed, the system restarts automatically.
Input Data
Data ID 1 ~ 5
Item
No.
Item Input Data Default
01 Restore Recovery Data [Restore & Reset?] : Dial 1 + press Hold
(Press Hold only to cancel.)
-
Conditions
None
Feature Cross Reference
None
SL1000/SL1100 ISSUE 3.01
2-618 Program 90 : Maintenance Program
Program