Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Level:
IN
Description
Use Program 34-01 : E&M Tie Line Basic Setup to define the basic settings for each E&M Tie line.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Item
No.
Item Input Data Description Default Related
Program
01 DID/E&M Start
Signaling
0 = 2
nd
Dial Tone
1 = Wink
2 = Immediate
3 = Delay
Set the start signaling mode for DID
and Tie trunks. DID and Tie trunks
can use either immediate start or
wink start signaling.
0 22-02
02 Receive Dial
Type for E&M Tie
Line
0 = DP
1 = DTMF
1 10-09
03 E&M Dial-In
Mode
0 = Specify Extension
Number (Intercom)
1 = Use Conversion
Table (NTT)
Determine if the incoming Tie Line
call should be directed as an inter-
com call or if it should follow the DID
Translation Table in Program 22-11.
0 22-11
04 E&M Line Dial
Tone
0 = Disable (No)
1 = Enable (Yes)
Enter 1 if the Tie Line should send
dial tone to the calling system after
the call is set up. Enter 0 if the Tie
Line should not send dial tone.
1
05 System Toll Re-
striction
0 = System
1 = Each Extension
Determine if an incoming Tie Line
call should be subject to Toll Re-
striction. If it is set to 0 then it will
use the Program 21-05-13, if it is set
to 1 then it will used Programs
21-05-01 ~ 21-05-13.
0 21-05
Conditions
None
Feature Cross Reference
None