Program 90 : Maintenance Program
90-06 : Trunk Control
Level:
SA
Description
Use Program 90-06 : Trunk Control for trunk maintenance. Busy Out lets you block a unit from
placing outgoing calls (just like placing the unit switch down). Once busied out, none of the ports on
the unit can be used for new calls. Existing calls, however, are not torn down.
Input Data
Menu Number
0 = Set Busy Out
1 = Reset Busy Out (idle)
Item
No.
Item Input Data Default
01 Trunk Control Trunk Port Number :
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
1
Conditions
None
Feature Cross Reference
None