Program 11 : System Numbering
11-04 : Virtual Extension Numbering
Level:
IN
Description
Use Program 11-04 : Virtual Extension Numbering to define the virtual extension numbers. The
extension number can have up to four (SL1000) eight (SL1100) digits. The first/second digit (s) of the
number should be assigned in Program 11-01 or Program 11-20.
Input Data
Virtual Extension Numbers 001 ~ 050
Item
No.
Item Input Data Description Default
01 Extension Number Dial (Up to 4 digits)
(SL1000)
Dial (Up to 8 digits)
(SL1100)
Set up Virtual Extension numbers.
The extension number cannot be dupli-
cated in Programs 11-02 and 11-07.
Virtual Port Num-
ber : Extension
Number
1 ~ 50 : No Set-
ting
Conditions
None
Feature Cross Reference
• Flexible System Numbering
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-67
Program
11