Program 12 : Night Mode Setup
12-05 : Night Mode Group Assignment for Extensions
Level:
IN
Description
Use Program 12-05 : Night Mode Group Assignment for Extensions to a assign Day/Night Mode
Group for each extension.
Input Data
Extension Number Up to four digits (SL1000)
Up to eight digits (SL1100)
Item
No.
Item Input Data Default
01 Night Mode Service Group Number 1 = Night Mode Group 1
2 = Night Mode Group 2
3 = Night Mode Group 3
4 = Night Mode Group 4
1
Conditions
None
Feature Cross Reference
Night Service
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-97