Program 10 : System Configuration Setup
10-03 : ETU Setup
Level:
IN
Description
Use Program 10-03 : ETU Setup to setup and confirm the Basic Configuration data for each unit.
When changing a defined terminal type, first set the type to 0 and then plug the new device in to have
the system automatically define it or you may have to reseat the unit.
The items highlighted in gray are read only and cannot be changed.
Input Data
Slot No. 00 ~ 16 (SL1000)
00 ~ 09 (SL1100)
For HBI PKG Setup (SL1000)
Physical Port Number
01 ~ 08
Item No. Item Input Data Default
01 Terminal Type 0 = No setting
1 = Multi-Line Telephone
2 = SLT
8 = Door Phone
10 = DSS Console
3 ~ 7, 9, 11, 12 = Not Used
2
02 Logical Port Number 1 ~ 128
03 Transmit Gain level for SLT 1 ~ 63
(- 15.5 ~ + 15.5dB)
32
04 Receive Gain level for SLT 1 ~ 63
(- 15.5 ~ + 15.5dB)
32
05 Select port type 0 = Hybrid Port
1 = Door Phone
0
06 Multi-Line Telephone Line 0 = None
1 = 12 Line
2 = 24 Line
For ESIU PKG Setup (SL1100)
Physical Port Number
01 ~ 08
SL1000/SL1100 ISSUE 3.01
2-4 Program 10 : System Configuration Setup