EasyManua.ls Logo

NEC SL 1000 - Page 27

NEC SL 1000
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item
No.
Item Input Data Description Default
01 Terminal Type (B1) 0 = No setting
1 = Multi-Line Telephone
10 = DSS Console
0
02 Logical Port Number 0 = No setting
1 = Multi-Line Telephone (1 ~
72)
10 = DSS Console (1 ~ 12)
0
10 Bottom option information 0 = None
4 = WHA
0
12 Multi-Line Telephone Line 0 = None
12 = 12 Line
Terminal Type (B1)
24 = 24 Line
This program can
only be change by us-
ing PC Program-
ming.
0
For SLIU PKG Setup (SL1100)
Physical Port Number 01 ~ 08
Item No. Item Input Data Default
01 Logical Port Number 0 ~ 120 0
03 Transmit Gain Level (S-Level) 1 ~ 63 (- 15.5 ~ + 15.5 dB) 32 (0 dB)
04 Receive Gain Level (R-Level) 1 ~ 63 (- 15.5 ~ + 15.5 dB) 32 (0 dB)
05 Select port type 0 = SLT
1 = Door Phone
0
For COIU Unit Setup
Physical Port Number
1 ~ 4
Item No. Item Input Data Default
01 Logical Port Number 1 ~ 48 (SL1000)
1 ~ 36 (SL1100)
0
02 Select port type (SL1000) 0 = Trunk
1 = Audio Port
0
For BRIU PKG Setup
ISDN Line Number
01 ~ 02
Item No. Item Input Data Description Default
01 ISDN Line Mode 0 = No setting
1 = T-Point
2 = S-Point
3 ~ 5= Not Used
6 = S-Point (Leased Line)
1
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-5
Program
10

Table of Contents

Other manuals for NEC SL 1000

Related product manuals