Item
No.
Item Input Data Default
34 Receive Digit Acknowledge min
Time
1 ~ 255 (4 ms ~ 1020 ms) 25 (100 ms)
35 Receive Digit Acknowledge max
Time
1 ~ 255 (4 ms ~ 1020 ms) 75 (300 ms)
36 Receive Meter Pulse min Time 1 ~ 255 (4 ms ~ 1020 ms) 25 (100 ms)
37 Receive Meter Pulse max Time 1 ~ 255 (4 ms ~ 1020 ms) 75 (300 ms)
38 Receive Line Block min Time 1 ~ 255 (64 ms ~ 16320 ms) 32 (2048 ms)
39 Receive Line Block recover min
Time
1 ~ 255 (64 ms ~ 16320 ms) 32 (2048 ms)
40 Transmit Remove Ring Time 0 ~ 255 (0 ms ~ 1020 ms) 0 (0 ms)
41 Transmit Clear Signal Send Time 1 ~ 255 (16 ms ~ 4080 ms) 63 (1008 ms)
42 Transmit Seizure Signal Time 1 ~ 255 (8 ms ~ 2040 ms) 100 (800 ms)
43 Group A Response Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
44 Group A Tone Complete Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
45 Group B Response Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
46 Group B Tone Complete Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
47 Group C Response Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
48 Group C Tone Complete Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
49 Group I Signal Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
50 Group I Tone Complete Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
51 Group II Signal Time 1 ~ 32 (1 sec ~ 32 sec) 12 (12 sec)
Conditions
• After set from Program 81-13-01 to 42, the E1 unit will be reset.
Feature Cross Reference
None
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-489
Program
81