EasyManua.ls Logo

NEC SL 1000 - Page 261

NEC SL 1000
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item
No.
Item Input Data Description Default Related
Program
10 Dial Digits for
Toll Restriction
Path
0 ~ 36 If this option is programmed with an
entry other than 0, a call does not
have a talk path unless the user di-
als at least the number of digits en-
tered in this option when placing an
outgoing call.
This means that an entry of 4 or
higher in this program causes a
problem when dialing 911 (USA on-
ly). Since it is only a 3-digit number,
the call does not have a talk path,
preventing the emergency dispatch-
er from hearing the caller. This op-
tion should be kept at its default set-
ting of 0 to prevent any problems
with dialing 911 (USA only).
0
11 Inter-Digit Time
for Toll Restric-
tion Path Control
0 ~ 60 seconds 10
12 Dial E911 Rout-
ing Without
Trunk Access
0 = Trunk Access Code
Required
1 = Trunk Access Code
Not Required
If enabled (1), an extension user
can dial 911 (USA only) without first
dialing a trunk access code or
pressing a line key. If disabled (0),
an extension user must dial a trunk
access code (e.g., 9) or press a line
key before dialing 911 (USA only).
1
13 Alarm Ring Tim-
er (E911)
0, 1~ 64800 seconds
(0 = Off)
Use this option to set the duration of
the E911 Alarm Ring Time. If set for
0, the E911 Alarm does not ring.
0 11-12-56
20-08-16
14 Forced Account
Code Inter-digit
Timer
0 ~ 64800 seconds If the user does not enter the ac-
count code in the amount of time
specified in this program the call will
be restricted.
3
15 Outgoing Disable
on Incoming Line
(Toll Restriction)
0 = Disable (Off)
1 = Enable (On)
Enable or disable the Outgoing Dis-
able on Incoming Line feature.
0 15-01-05
21-01-16
21-01-17
80-03-01
16 Supervise Dial
Detection Timer
0 ~ 64800 seconds With the Outgoing Disable on In-
coming Line feature, if dial tone is
not detected after the extension an-
swers an incoming line, the system
determines the call is unable to
complete and releases the DTMF
receiver.
20 15-01-05
21-01-16
21-01-17
80-03-01
17 Restriction Digit
in Outgoing Dis-
able on Incoming
Line
Digits 1 ~ 9 With the Outgoing Disable on In-
coming Line feature, determine the
number of digits to be dialed before
the call should be disconnected.
4 15-01-05
21-01-15
21-01-16
80-03-01
18 Reset Dial After
Failure of Trunk
Access
0 = Disable (Off)
1 = Enable (On)
Enable (1) or Disable (0) the ability
to continue to dial codes or exten-
sions after receiving Trunk Busy.
This needs to be set to Enabled (1)
for the Forced Trunk Disconnect
feature to work.
0
19 Do-Not-Call-Set-
up
0 = No service
1 = Extented common
restriction
0 15-01-07
Conditions
None
ISSUE 3.01
SL1000/SL1100
Programming Manual 2-239
Program
21

Table of Contents

Other manuals for NEC SL 1000