EasyManua.ls Logo

NEC SL 1000 - Page 317

NEC SL 1000
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item
No.
Item Input Data Description Default Related
Program
09 Two B-Channel
Transfer Retry
Timer
0 ~ 30 seconds 10 10-03-16
(PRI)
10 Disconnect
Trunk-to-Trunk
0 ~ 64800 seconds 0 14-01-25
20-28-01
20-28-02
20-28-03
24-02-07
11 No Answer Step
Transfer
0 ~ 64800 seconds 10 14-01-26
12 No Answer
Trunk-to-Trunk
Transfer
0 ~ 64800 seconds 0 14-01-26
13 Hook Flash
Sending Timer
When the Sys-
tem Answers Au-
tomatically
0 ~ 64800 seconds Time before sending the hook flash
for Call Forward Centrex.
2
15 SIP Out of Range
Timer (V3.0 Add-
ed)
0 ~ 30 seconds When not receiving any response
within this timer setting, the system
determines that the SIP terminal is
out of range. When set to 0, timer is
invalid.
4
Conditions
None
Feature Cross Reference
Transfer
ISSUE 3.01 SL1000/SL1100
Programming Manual 2-295
Program
24

Table of Contents

Other manuals for NEC SL 1000