Section 2 NS Series Functions 2-8 Common Functional Object Functions
2-99
NS Series Programming Manual
The supported flicker methods depend on the functional or fixed object.
Show and hide
alternately
Specify display color
Functional/Fixed object
Show
display
color and
inverse
color
alternately
Whole
object
Label Text color
Background
color
Line color
ON/OFF buttons
×
Word buttons ×
Command buttons ×
Bit lamps ×
Word lamps ×
Labels ×
Numeral display and
input
×
String display and
input
×
List Selection × × × × ×
Thumbwheel switch × × × × ×
Analog meter × × × × ×
Level meter × × × × ×
Broken-line graph × × × × ×
Bitmaps × × × × ×
Alarm/event display
(See
note 1.)
(See
note 1.)
×
Alarm/Event
Summary/History
× × × × ×
Date ×
Time ×
Data Log Graph × × × × ×
Video Display
Temporary Input
Continuous Line
Drawings
Contents Display
(for string display)
×
Contents Display
(for image display)
× × × ×
Multifunction Object
(See
note 3.)
Data Block Table
Rectangle × ×
Circle/Oval × ×
Straight Line
(See
note 2.)
× ×
Continuous Straight
Line
(See
note 2.)
× ×
Polygon × ×
Sector × ×
Arc
(See
note 2.)
× ×
: Flicker, ×: No flicker, : Action depends on settings, – : Flicker function not supported
Note 1: The object will not flicker if Flowing text is selected in the alarm/event display property settings.
2: The whole object will flicker, regardless of the flicker range settings.
3: The object will flicker only if the shape is set as a polygon or sector.