3-29
S Auto-tuning Operation Example
Key sequence Display Explanation
** Main Menu **
Operation
Displays operation mode.
3 times
** Main Menu **
Auto-Tuning
Displays auto-tuning mode.
Rated Voltage
200.0 VAC
Displays the rated voltage.
Rated Voltage
200.0 VAC
When changing the rated voltage, press the Enter Key
again to enter input mode. (The digits will flash.)
Rated Voltage
200.0 VAC
Use the Reset, Up Arrow and Down Arrow Keys to
change the rated voltage setting.
Entry Accepted
Writes the new setting.
Rated Voltage
200.0 VAC
Returns to the rated voltage display.
Rated Current
1.90 A
Displays the rated current.
Follow the procedure used to change for the rated volt-
age when changing this setting.
Rated Frequency
60.0 Hz
Displays the rated frequency.
Follow the procedure used to change for the rated volt-
age when changing this setting.
Rated Speed
1750 RPM
Displays the rated speed.
Follow the procedure used to change for the rated volt-
age when changing this setting.
Number of Poles
4
Displays the number of poles.
Follow the procedure used to change for the rated volt-
age when changing this setting.
Select Motor 1/2
1
Displays the motor selection.
(Selection of motor 1 parameter or motor 2 parameter)
Tuning Ready ?
Press RUN key
Displays a confirmation prompt for the start of the
auto-tuning function. (The lower line will flash.)
Tune Proceeding
HZ

A
Starts the auto-tuning function.
(The upper line will flash.)
Tune Successful Indicates the completion of auto-tuning.
** Main Menu **
Operation
Returns to the operation mode display.