7-30
Para
meter
No.
PageControl
mode
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
DescriptionNamePara
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chan-
ges
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
F1-02
PG discon-
nection
stopping
method
(PGO)
Sets the PG disconnection
stopping method.
0:
Ramp to stop (Deceleration
stop using deceleration time
1, C1-02.)
1:
Coast to stop
2: Fast stop (Emergency stop
0 to 3
1 NO X B X B 5-31,
5-47
PG Fdbk
Loss Sel
using the fast-stop time,
C1-09.)
3:
Continue operation (This
setting can’t be made with
flux vector control.)
F1-03
PG
overspeed
stopping
method
Sets the stopping method when
an overspeed (OS) fault occurs.
0:
Ramp to stop (Deceleration
stop using deceleration time
1, C1-02.)
1:
Coast to stop
p
0 to 3
1 NO X B X B 5-31,
5-48
PG
OverSpeed
Sel
2: Fast stop (Emergency stop
using the fast-stop time,
C1-09.)
3:
Continue operation (This
setting can’t be made with
flux vector control.)
F1-04
PG speed
deviation
stopping
method
Sets the stopping method when
a speed deviation (DEV) fault
occurs.
0:
Ramp to stop (Deceleration
stop using deceleration time
1, C1-02.)
1:
Coast to stop
0 to 3
3 NO X B X B 5-32,
5-48
PG
Deviation
Sel
2: Fast stop (Emergency stop
using the fast-stop time,
C1-09.)
3:
Continue operation (DEV is
displayed and control
continued.)
F1-05
PG rotation
setting
0:
Phase A leads with forward
command. (Phase B leads
0, 1
0 NO X B X B 5-30
PG
Rotation
Sel
w
1:
Phase B leads with forward
command. (Phase A leads
with reverse command.)
F1-06
PG output
ratio
Sets the division ratio for the
PG speed control card pulse
output.
Division ratio = (1+ n) /m (n=0,1
m=1 to 32)
F1 - 06 =
1
to
132
1 NO X B X B 5-30
PG Output
Ratio
Note:
This parameter is only ef
-
fective when a 3G3FV
-
PPGB2 is used.
The possible division ratio
settings are:
1/32)F1-06)1.
m
n
Parameter Lists Chapter
7