EasyManua.ls Logo

Omron SYSDRIVE 3G3FV - Page 77

Omron SYSDRIVE 3G3FV
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-45
I/O Circuit Configuration
+12 V
0 V
PG power
supply +12 V
A-phase
pulse input
B-phase
pulse input
A-phase pulse
monitor output
B-phase pulse
monitor output
Forward output pulses
A-phase pulses
B-phase pulses
A-phase
pulses
B-phase
pulses
Division rate circuit
Note When
connecting to a voltage-output-type PG (encoder), select
a PG that has an output imped
-
ance
with a current of at least 12 mA to
the input circuit photocoupler (diode). The E6B2-CWZ3E
cannot be used.
D 3G3FV-PPGD2 (For V/f With PG Feedback Mode Only)
Encoder
Power supply 0 V
Power supply 5 V
Pulse output + (A/B phase)
Pulse output –
(A/B phase)
Three-phase
200 VAC (400 VAC)
Pulse monitor output
L1
L2
L3
T1
T2
T3
3G3FV-PPGD2
Note 1. Twisted-pair shielded wire must be used for signal lines.
Note 2. Do not use the pulse generator’s power supply for anything other than the pulse generator
(encoder). Using it for another purpose can cause malfunctions due to noise.
Note 3. The length of the pulse generator’s wiring must not be more than 50 meters.
Installation Chapter
2

Table of Contents

Related product manuals