10-22
Para
me-
ter
No.
Reg-
ister
No.
(Hex)
Name Description Set-
ting
range
Unit
of
set-
ting
Defa
ult
set-
ting
Chan-
ges dur-
ing
opera-
tion
Ref-
er-
ence
page
n089 0159 DC injec-
tion brak-
ing current
Used to impose DC on the induction motor for
braking control.
Sets the DC brakin
g
current as a
p
ercenta
g
e
0 to
100
1% 50 No 6-26
n090 015A DC injec-
tion brak-
ing-to-stop
time
Sets the DC braking current as a percentage
based on the rated current of the Inverter as
100%.
Output
frequency
0.0 to
25.5
0.1 s 0.5 No 6-26
n091 015B Startup DC
injection
braking
time
frequency
Time
Minimum
output
frequency
(n016)
n091 n090
0.0 to
25.5
0.1 s 0.0 No 6-26
n092 015C Stall pre-
vention
during
decelera-
tion
Used to select a function to change the decel-
eration time of the motor automatically so that
there will be no overvoltage imposed on the
motor during deceleration.
0: Stall prevention during deceleration enabled
1: Stall prevention during deceleration disabled
* Be sure to set the parameter to 1 when the
Braking Resistor Unit or a braking resistor is
used as an option.
0, 1 1 0 No 6-27
n093 015D Stall pre-
vention
level dur-
ing accel-
eration
Used to select a function to stop the accelera-
tion of the motor automatically for stall preven-
tion during acceleration.
Sets the level as a percentage based on the
rated current of the Inverter as 100%.
30 to
200
1% 170 No 6-28
n094 015E Stall pre-
vention
level dur-
ing opera-
tion
Used to select a function to reduce the output
frequency of the Inverter automatically for stall
prevention during operation.
Sets the level as a percentage based on the
rated current of the Inverter as 100%.
30 to
200
1% 160 No 6-29
n095 015F Frequency
detection
level
Used to set the frequency to be detected.
* The parameter n059 for multi-function out-
put must be set for the output of frequency
detection levels 1 and 2.
0.00
to
400.0
0.01
Hz
0.00 No 6-44
n096 0160 Overtorque
detection
function
selection 1
Used to enable or disable overtorque detection
and select the processing method after over-
torque detection.
0: Overtorque detection disabled
1: Overtorque detection only when speed coin-
cides and operation continues (issues
alarm)
2: Overtorque detection only when speed coin-
cides and output turned OFF (for protection)
3: Overtorque always detected and operation
continues (issues alarm)
4: Overtorque always detected and output
turned OFF (for protection)
0 to 4 1 0 No 6-31
n097 0161 Overtorque
detection
function
selection 2
Select the item to detect overtorque.
0: Detected from output torque.
1: Detected from output current.
0, 1 1 0 No 6-32
List of Parameters Chapter 10