Servicing the CMIOU Chassis
SPARC M8-8 and SPARC M7-8 servers each have a single CMIOU chassis. For the
location of the chassis, see “Server Front Components (SPARC M8-8 and SPARC M7-8
Servers)” on page 16.
SPARC M7-16 servers have two CMIOU chassis and a single switch chassis. For the locations
of these chassis, see “Server Front Components (SPARC M7-16)” on page 18.
The steps involved in replacing either of these chassis are the same.
Caution - This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause server components to fail. Follow antistatic precautions to
prevent electrostatic damage. See “Prevent ESD Damage” on page 61.
These topics explain how to service the CMIOU chassis.
“Remove a CMIOU Chassis” on page 269
“Install a CMIOU Chassis” on page 275
Related Information
“Identifying Components” on page 15
“Detecting and Managing Faults” on page 35
“Preparing for Service” on page 57
“Controlling the Server and Domains” on page 67
“Understanding Server Configurations and Failover Behavior” on page 79
Remove a CMIOU Chassis
This is procedure can be performed only by qualified service personnel. Remove AC power
using the circuit breakers on the appropriate PDU before performing this procedure.
Servicing the CMIOU Chassis 269

Table of Contents

Other manuals for Oracle SPARC M8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC M8 and is the answer not in the manual?

Oracle SPARC M8 Specifications

General IconGeneral
BrandOracle
ModelSPARC M8
CategoryServer
LanguageEnglish

Related product manuals