EasyManua.ls Logo

Parker PD-04 Series

Parker PD-04 Series
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin
P series User Guide 108
19
position actual value
UU
20
position demand value
UU
21
Position command speed
rpm
Table 67. Analog Monitor Channel Setting
The voltage for analog monitor output is calculated using the following formulas.
Channel 1 output voltage [V] = [monitoring signal value (0x2221) offset (0x2203)] /
scale (0x2205)
Channel 2 output voltage [V] = [monitoring signal value (0x2222) offset (0x2204)] /
scale (0x2206)
5.8.4 Setting Example
The figure below shows an example of monitoring when driving with speed feedback
signal of 1000rpm.
Monitors signals by
amplifying them 5
times
Output offset : 1000 rpm
Output scale : 500rpm/V
Output offset : 0 rpm
Output scale : 500rpm/V
Output offset : 1000 rpm
Output scale : 100rpm/V
Figure 37. Setting Example

Table of Contents

Related product manuals