Parker Hannifin
P series User Guide 108
Table 67. Analog Monitor Channel Setting
The voltage for analog monitor output is calculated using the following formulas.
Channel 1 output voltage [V] = [monitoring signal value (0x2221) –offset (0x2203)] /
scale (0x2205)
Channel 2 output voltage [V] = [monitoring signal value (0x2222) –offset (0x2204)] /
scale (0x2206)
5.8.4 Setting Example
The figure below shows an example of monitoring when driving with speed feedback
signal of 1000rpm.
Monitors signals by
amplifying them 5
times
Output offset : 1000 rpm
Output scale : 500rpm/V
Output offset : 0 rpm
Output scale : 500rpm/V
Output offset : 1000 rpm
Output scale : 100rpm/V
Figure 37. Setting Example