Parker Hannifin
P series User Guide 58
Figure 20. Example of Digital Output Signal Wiring
Note) For output signals DO1~ DO8, GND24 terminal is disconnected GND24.
Example of Analog Input Signal Wiring
Please see 8.5 Analog Speed Override and 6.8.3 Torque Limit Setting for
operation of analog input signals.
The window if analog input signal is -10V ~ 10V.
Impedance of the input signals is approximately 22KΩ.
Example of resistance selection
R1
R2
5KΩ
6KΩ
10KΩ
12KΩ
Figure 21. Example of Analog Input Signal Wiring
Example of Analog Output Signal Wiring
Please see 5.8 Analog Monitor for setting and scale adjustment of monitoring
signals. The window of analog output signal is -10V ~ 10V.
The resolution of analog output signals is 12bit.
The permissible maximum load current is 2.5[mA] or below.
The stabilization time is 15[us].