EasyManua.ls Logo

Parker PD-04 Series

Parker PD-04 Series
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin
P series User Guide 144
Analog Torque
Limit
(Set Value 4)
The torque is limited using the torque limit value depending on the
analog input voltage.
- Regardless of the positivity/negativity of analog input voltage, when
inputting +/-10[V], the torque is limited in the forward/reverse direction
with 300[%]torque
- The relationship between analog input voltage and torque limit is as
follows.

Table of Contents

Related product manuals