7. Use the position thumbwheels to center the laser beam. Use the top
thumbwheel to move the beam up/down. The side thumbwheel is used to move
the beam sideways.
8. After centering the laser beam, press
ß to return to the soft foot screen. Press
e to proceed with measurement.
9. With foot to be measured highlighted, press
e. A wrench (spanner) symbol
appears on the screen. Loosen the corresponding foot bolt.
The laser beam should
be adjusted such that the
needle of the delta angle
on-screen indicator rests
preferably in the middle of
the green sector.
If machine dimensions
have not been entered,
pressing
e prompts the
entering of the missing
dimension.
Before starting soft foot
measurement, the “Soft
foot measurement”
screen context menu item
‘SF tolerance’ may be used
to edit soft foot tolerance
value (0.05 mm is the