ROTALIGN Ultra iS Shaft handbook
34
3.3.4 Measurement
Pressing
m twice activates auto measurement.
In auto measurement any of the three measurement modes – IntelliSWEEP,
Multipoint or Static measurement is started directly by the appropriate action.
IntelliSWEEP mode is activated by rotating the shafts
Multipoint is started by pressing
e
Static measurement is started by pressing either the data entry keys or any
of the navigation keys
3.3.5 Results
Pressing
f or g while in results, cycles the results between vertical (V),
horizontal (H) and both H&V.
Pressing
f or g long enough zooms out or zooms in the results image
respectively.
In auto measurement any of the three measurement modes – IntelliSWEEP,
Mu