79
4.15.3 To print report after measurement
Measurement files can be printed either direct from the results screen or from the
shaft alignment overview screen.
a) Connect the ROTALIGN Ultra iS computer to your printer using the USB/
peripheral devices cable ALI 12.503. Depending on your printer interface, you
may require an A to B USB cable. Most printers are delivered with this USB cable
which is also readily available from most electronic goods dealers.
b) Press
ß repeatedly until the machine configuration overview appears on the
display screen. Press
q. The context menu appears.
c) Select ‘Report’ using either
f/g then confirm selection by pressing e.
A to B USB cable
USB/peripheral devices
cable ALI 12.503
Saving and printing