ROTALIGN Ultra iS Shaft handbook
66
Press e to confirm changing the orientation of the machines. Results will now be
displayed as currently viewed by the user. This is from the opposite side of the original
position.
Any applied ‘Rotation view’ functionality is temporary and is available only in
the “Results”, “Move” and “Move simulator” screens. As soon as one reverts to
the either the “Set-up” or “Measurement” or “Soft foot” screens, the original
machine orientation is reassumed.
4.13.1.6 V/H views
The screen on the left above, shows the initial orientation as viewed by the user, while the screen on the right above
shows the current orientation after the ‘Rotation view’ function was applied. In the screen on the right, the machine
designated stationary is now on the right hand side. Note that the vertical coupling gap values for both orientations
remains unaltered as are the horizontal coupling offset values. The applied sign convention holds valid for both
orientations.
Note
An
.
The different views may
also be cycled by pressing
g.
In this example following
results options have been
selected:
‘Show both left and right
envelopes’, ‘Show machine
icons’, ‘Show correction
arrows’