117
5.2.11 Measurements options screen
The “Measurement options” screen may be accessed via the “Measurement” screen
context menu item ‘Measurement options. The context menu opens by pressing
q
while in the “Measurement” screen. Use
f/g and highlight ‘Measurement
options’.
With ‘Measurement options’ highlighted, press
e to confirm selection.
The “Measurement options” screen may be used to set the following selections:
Whether Sweep measurement mode is started manually [by pressing
e]
or automatically when shafts are rotated
Whether measurement points are taken manually [by pressing
e] or
automatically in Multipoint measurement mode – automatic collection of
measurement points is based on stability filter parameters and may be used in
Multipoint, IntelliPOINT and cardan shaft measurements
Whether results resolution is set to two or three decimal places
Whether the standard deviation is displayed on the screen or not
Alternatively, access the
“Measurement options”
screen directly using
the global menu. Press
q twice to open
the global menu, then
select ‘Measurement’ ->
‘Measurement options’.
Measurement options screen