ROTALIGN Ultra iS Shaft handbook
138
12. To investigate the soft foot, press q. The context menu appears. Use
f/g to highlight ‘Diagnose’. ROTALIGN Ultra iS Shaft presents the user
with concise instructions on how to eliminate the prevailing soft foot.
13. Press
e to proceed. A hint appears requesting confirmation as to whether the
soft foot measurement should be ended and diagnosis started.
14. Use
i/h to highlight ‘Yes’ confirming selection by pressing
e, then proceed
with diagnosis using the soft foot wizard.