Error Codes
SM 23 D649
Fax Option
Type C305
(D649)
Code Meaning Suggested Cause/Action
0-21
EOL signal (end-of-line)
from the other end not
received within 5 s of the
previous EOL signal
Check the connections between the FCU and
line.
Check for line noise or other line problems.
Replace the FCU.
The remote machine may be defective or may
have disconnected.
Cross reference
Maximum interval between EOLs and between
ECM frames - G3 Bit Switch 0A, bit 4
0-22
The signal from the other
end was interrupted for
more than the acceptable
modem carrier drop time
(default: 200 ms)
Check the line connection.
Replace the FCU.
Defective remote terminal.
Check for line noise or other line problems.
Try adjusting the acceptable modem carrier
drop time.
Cross reference
Acceptable modem carrier drop time - G3 Switch
0A, bits 0 and 1
0-23
Too many errors during
reception
Check the line connection.
Replace the FCU.
Defective remote terminal
Check for line noise or other line problems.
Try asking the other end to adjust their tx level.
Try adjusting the rx cable equalizer setting
and/or rx error criteria.
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
Rx error criteria - Communication Switch 02, bits 0
and 1
0-30
The other terminal did not
reply to NSS(A) in AI short
protocol mode
Check the line connection.
Try adjusting the tx level and/or cable
equalizer settings.
The other terminal may not be compatible.
Cross reference
Dedicated tx parameters - Section 4