Measurements and Result Displays
R&S
®
ESW
133User Manual 1177.6298.02 ─ 08
"Transducer"
Draws a trace that shows the correction values of all active trans-
ducer factors in the currently selected frequency range. In case trans-
ducer factors overlap each other, the correction values are aggrega-
ted.
Available for Trace 1 and in the receiver application only.
Note: When you select the "Transducer" trace, the application tempo-
rarily removes all other traces from the diagram. You can restore the
scan traces by selecting the original trace mode of trace 1 again.
Remote command:
DISPlay[:WINDow<n>]:TRACe<t>:MODE on page 474
View transducer: [SENSe:]CORRection:TRANsducer:VIEW on page 472
Detector
Selects the trace detector.
Note: In the receiver application, you can apply different detectors to the bargraph, the
scan and the final measurement.
"Max Peak"
Selects the Max or Positive Peak detector.
"Min Peak"
Selects the Max or Positive Peak detector.
"RMS"
Selects the RMS detector.
"Average"
Selects the Average detector.
"Quasipeak"
Selects the Quasipeak detector.
"CISPR Aver-
age"
Selects the CISPR Average detector.
"RMS Aver-
age"
Selects the RMS Average detector.
"None"
Ignores the corresponding trace during the final measurement.
Available for the final measurement.
Remote command:
Bargraph: [SENSe:]DETector<t>:RECeiver[:FUNCtion] on page 451
Scan: [SENSe:]DETector<t>[:FUNCtion] on page 455
Final measurement: [SENSe:]DETector<t>:FMEasurement on page 473
Interactive
Turns interactive measurements on and off.
For more information, see "Automatic vs interactive final measurements" on page 130.
Remote command:
[SENSe:]FMEasurement:AUTO on page 473
9.3.5.2 Working with the Final Measurement Results
Access: "Overview" > "Test Automation" > "Final Result"
When the final measurement is done, the R&S ESW writes the results into a table that
looks and feels similar to the peak list. Editing entries is, however, not possible.