Remote Control Commands
R&S
®
SMA100B
575User Manual 1178.3834.02 ─ 05
INT
Internal modulation source is used.
EXT|INT,EXT
An external modulation source is used, additional to the internal
modulation source.
The external signal is input at the Ext connector.
Example: See Example "Configure and generate a VOR signal"
on page 544.
[:SOURce<hw>]:VOR[:BANGle] <BAngle>
Sets the bearing angle between the VAR signal and the reference signal.
The orientation of the angle can be set with [:SOURce<hw>]:VOR[:BANGle]:
DIRection.
Parameters:
<BAngle> float
Range: 0 to 360
Increment: 0.01
*RST: 0
Example: See Example "Configure and generate a VOR signal"
on page 544.
Manual operation: See "Bearing Angle" on page 121
[:SOURce<hw>]:VOR[:BANGle]:DIRection <Direction>
Sets the reference position of the phase information.
Parameters:
<Direction> FROM | TO
FROM
The bearing angle is measured between the geographic north
and the connection line from beacon to airplane.
TO
The bearing angle is measured between the geographic north
and the connection line from airplane to beacon.
*RST: FROM
Example: See Example "Configure and generate a VOR signal"
on page 544.
Manual operation: See "Direction" on page 121
[:SOURce<hw>]:VOR:COMid:CODE <Code>
Sets the coding of the COM/ID signal by the international short name of the airport
(e.g. MUC for the Munich airport).