Remote Control Commands
R&S
®
SMA100B
605User Manual 1178.3834.02 ─ 05
Example: See Example "Configuring the LF generator" on page 600.
Manual operation: See "Output Voltage" on page 105
[:SOURce]:LFOutput:OFFSet <Offset>
Sets a DC offset at the LF Output.
Parameters:
<Offset> float
Range: depends on lfo voltage
Increment: 0.001
*RST: 0
Example: See Example "Configuring the LF generator" on page 600.
Manual operation: See "DC-Offset" on page 105
[:SOURce]:LFOutput<ch>:SOURce
<Source>
Determines the LF signal to be synchronized, when monitoring is enabled.
Parameters:
<Source> LF1 | LF2 | NOISe | AM | FMPM | EXT1 | | EXT2
LF1|LF2
Selects an internally generated LF signal.
NOISe
Selects an internally generated noise signal.
EXT1|EXT2
Selects an externally supplied LF signal
AM
Selects the AM signal.
FMPM
Selects the signal also used by the frequency or phase modula-
tions.
*RST:
LF1
Example: See Example "Configuring the LF generator" on page 600.
Manual operation: See "Source" on page 105
[:SOURce]:LFOutput<ch>:SOURce:PATH <SourPath>
Determines the path of the LF output source.
Parameters:
<SourPath> A | B
*RST: A
Example:
LFO:SOUR:PATH?
Queries the currently set path for the LF output signal source.